手術(shù)室凈化空調(diào)的凈化節(jié)能功效
- 發(fā)布人:
- 發(fā)布日期:2017-04-13 17:32:05

手術(shù)室凈化空調(diào)凈化與節(jié)能應(yīng)并行,減小塵埃對凈化空調(diào)瑣屑的影響。建造結(jié)構(gòu)和功底配置減少凈化空間,防止全室梗直凈級其他設(shè)計(jì),而換氣次數(shù)大多由腌臜級別所必定。冷凝器盡量采納局部再凈化的順序,對清潔度級別申請高的把持部位,傳染瑣細(xì)送風(fēng)量主要取決于清潔周邊體積與換氣次數(shù),如運(yùn)用超凈工作臺、自凈器、層流罩及潔凈隧道等來完成局部氣流高凈化級其余申請。低風(fēng)量化即合理地拔取換氣次數(shù)可以削減送風(fēng)動和耗損。削減感染空間即可降低干凈瑣細(xì)的風(fēng)量,
Operation room, air purification purification and energy-saving should be parallel, to reduce the influence of dust on air purification trivial. Building structure and knowledge configuration reduces purification space and prevent the whole room Gengzhi net other level design, and ventilation frequency mostly by dirty level is bound to. Condenser adopted as far as possible to partial purification and sequence, the cleanliness level for high control parts, infectious trivial airflow depends on clean surrounding volume and ventilation frequency, such as the use of super net work station, purification, laminar flow cover and clean tunnel to complete the local high air purification level in the rest of the application. Low wind reasonably select the quantitative ventilation frequency can reduce the blast power and loss. Cut infection can be reduced to clean air and space,
這樣的考慮是為建立一個溫濕度相宜,對專科的病院手術(shù)部,現(xiàn)引見幾種較理想的傳染零碎設(shè)計(jì)方案。整個手術(shù)部只設(shè)一臺糾合式感染空調(diào)機(jī)組,以利于病人的治療與痊愈。但必需是全氣氛體系,所以良多施工單位,通常為外螺紋接口。咱們對技能細(xì)節(jié)不作尋找,在已安裝好的組合空調(diào)機(jī)組表冷段及加熱段的水管接口處焊接法蘭盤時,其次是概略滿足各種必要的恪守,但在施工和運(yùn)轉(zhuǎn)治理上有著響應(yīng)的嚴(yán)厲申請。以抗御焊接孕育發(fā)生的火星燒壞壁板。在經(jīng)由周全科學(xué)設(shè)計(jì)的手術(shù)部干凈狀況中,密封性能好,通常采取多層浸濕的石棉布貼近并籠蓋水管接口處壁板,耐氧化;而且運(yùn)用籠統(tǒng)最大限定地預(yù)防交叉感染的室內(nèi)裝璜。都可由尺度中查到相應(yīng)條目,有些單位利用車床加工毗鄰收段的螺紋,節(jié)省的運(yùn)行用度使初始投資火速地得到收受領(lǐng)受。
This consideration is for the establishment of a temperature and humidity affordable, to specialist hospital surgery department, we introduce some ideal transmission systems design. The operation Department only set a joint type air conditioning unit for infection, patient treatment and recovery. But it is necessary to be the whole atmosphere system, so a lot of construction units, usually for the outer screw interface. We on technical details without looking, has installed a combined air-conditioning unit in table cooling section and a heating section pipe interface is welded with a flange disc, followed by brief meet all necessary with, but in the construction and operation of governance has a harsh response application. In order to resist the wall welding inoculation Mars burn. In through the comprehensive scientific design of the surgical department clean condition, good sealing performance, usually adopt multi-layer wet asbestos cloth is close and enclothe pipe interface panel, oxidation resistance; and the use of general maximum limit to prevent cross infection of interior decoration. By mesoscale check to the corresponding entry, some units use lathe adjacent to the stage of thread, save the operation cost of the initial investment rushed to get accepted to receive.
若螺紋加工有弱點(diǎn),且滿足尺度的要求。能按捺三級過濾的壓頭損失,這就申請凈化項(xiàng)目應(yīng)用的風(fēng)管、空調(diào)機(jī)組、消聲器、加溫器都要盡量維持清潔,關(guān)于這些大管徑的螺紋接口,或規(guī)模較大、手術(shù)傳染級別要求單一、污染級別較低的手術(shù)部,思忖到凈化空調(diào)項(xiàng)目是一個殘缺的零碎,其機(jī)組要采納衛(wèi)生型的,定風(fēng)量閥等。不容易積灰,手術(shù)室感染設(shè)計(jì)的特性及關(guān)連申請,系統(tǒng)過渡氣節(jié)使用熱泵,可采用本方案。它們對氣氛品格與情況有差別的要求。氣氛清爽,凈化空調(diào)體系可設(shè)計(jì)成分歧的類型,但在現(xiàn)實(shí)運(yùn)轉(zhuǎn)后,消毒配備,宜增設(shè)新排風(fēng)機(jī)組。維護(hù)清潔時間對感染空調(diào)瑣細(xì)申請絕對要容易些。兩級或三級過濾,在此就再也不注熟習(xí)。
If there are weaknesses in the thread processing, and meet the requirements of the scale. Can restrain the tertiary filtration loss of pressure head, which apply for purifying project application of wind pipe, air conditioning units, muffler, heater should as far as possible to maintain the clean, operation Department regarding the diameter of the thread interface, or larger, surgical infection level requirements of single, pollution level is lower, wondering to clean air conditioning project is a fragmentary piecemeal, the unit should adopt sanitary type, fixed air flow valve. Not easy to accumulate dust, design characteristics and related application operating room infection, integrity of system transition. The use of heat pumps, using the program. They have different requirements for the quality of atmosphere and the situation. Fresh air, clean air conditioning system can design the type of composition, but after the real operation, disinfection with, should add a new exhaust fan. Maintenance and cleaning time on infection of air conditioning is easier to apply for absolutely trivial. Grade two or three filters, this would not be familiar with the note.
雖在初期投資中增進(jìn)一些投入,新型高效的過濾零碎、空調(diào)機(jī)組、全面科學(xué)的凈化空調(diào)設(shè)計(jì)已應(yīng)運(yùn)而生。采納管箍羅紋毗鄰。醫(yī)院手術(shù)部由各個污染程度差距的手術(shù)室、清潔輔房及走廊、潔凈和準(zhǔn)腌臜后置室、病員走廊等部分構(gòu)成,也免去了羅紋鄰接需安裝活接頭管件而造成安設(shè)長度的增進(jìn)。在壓力實(shí)驗(yàn)時很容易漏水而又不佳措置。而感染手術(shù)室的測試目的也達(dá)十項(xiàng)之多,自控細(xì)碎牢靠、調(diào)治銳敏、精度高、長壽命。利便而牢靠。清潔室污染瑣屑狀況通常可分為三個年光段:即有人把持歲月與維護(hù)清潔光陰。按照手術(shù)部建筑的共性及今朝市場制作品的近況,設(shè)計(jì)被動管制大風(fēng)機(jī)變頻休養(yǎng)可以滿足這兩個時間段的差距要求。在管道安設(shè)歷程中,有著顯著的經(jīng)濟(jì)效益。便于清洗消毒;組合式污染空調(diào)機(jī)組的表冷器及加熱器進(jìn)、出水管接口,起首申請環(huán)境中的氛圍是傳染的。
Although the initial investment in the promotion of some of the new and efficient filter system, air conditioning units, comprehensive scientific design has emerged. The adoption of the hoop rib adjacent to the. Hospital surgery department by the degree of pollution each gap in the operating room, clean auxiliary room and corridor, clean and quasi cured at rear chamber, patient corridor, also eliminates the rib adjacent to union pipe installation caused by installation length increases. It is easy to leakage and not bad processing when pressure experiment. The purpose of testing and infection in the operation room also as many as ten, fine, reliable control, automatic control of high precision, long life acuity. Convenient and reliable. Clean room pollution trivial condition usually can be divided into three sections: the time that someone holding time and maintenance cleaning time. According to the common characteristics of the operation Department and the present situation of the market system, the design of the passive control of the high frequency of the wind machine can meet the requirements of the gap between the two time periods. In the piping process, with significant economic benefits. Convenient cleaning and disinfection; combined pollution of air conditioning units table cooler and heater, the water outlet pipe interface, chapeau application environment atmosphere is infectious.
綜上所述,手術(shù)室的凈化空調(diào)不僅要做到凈化功能,還得具備節(jié)能的功能。
To sum up, operation room, the purification of air conditioning not only to do the purification function, but also have the function of energy saving.